BestTools / Guides / NCC stair rules: risers, goings and 2R + G

NCC stair rules: risers, goings and 2R + G

Common NCC guidance for stairs in houses (Class 1 and 10 buildings): risers 115–190 mm, goings 240–355 mm, and 2R + G between 550 and 700 mm. Risers and goings should be the same all the way up a flight. Always confirm with your certifier.

LimitMinimumMaximum
Riser (R)115 mm190 mm
Going (G)240 mm355 mm
2R + G550 mm700 mm

Risers for common floor heights

Assumes a preferred riser of about 175 mm and a 250 mm going.

Floor to floorRisersRiser heightTreadsTotal going2R + G
2400 mm14171.4 mm133,250 mm593 mm
2500 mm14178.6 mm133,250 mm607 mm
2600 mm15173.3 mm143,500 mm597 mm
2700 mm15180.0 mm143,500 mm610 mm
2800 mm16175.0 mm153,750 mm600 mm
2900 mm17170.6 mm164,000 mm591 mm
3000 mm17176.5 mm164,000 mm603 mm
3100 mm18172.2 mm174,250 mm594 mm
3200 mm18177.8 mm174,250 mm606 mm
3300 mm19173.7 mm184,500 mm597 mm
3400 mm19178.9 mm184,500 mm608 mm

Stair calculator

Estimates only. Check sizes, coverage and quantities with your supplier, engineer or certifier before ordering. Standards references are a guide, not compliance advice.